# CCTV Camera Configuration — Add ONVIF, RTSP and IP Cameras

## Overview

This is the step that connects your cameras to the **smart CCTV monitoring** platform. OWL EYE
ALERTS supports five source types, so almost any camera already on your network can be added:

| Source type | When to use it |
|---|---|
| **ONVIF** | Modern IP cameras and NVRs; discovery and auto-configuration |
| **RTSP** | Any camera with a stream URL, including older or non-ONVIF models |
| **WEBCAM** | The PC's own USB camera, useful for testing |
| **MJPEG** | Cameras exposing a motion-JPEG HTTP stream |
| **JPEG** | Cameras that only publish a still image at a URL |

Do one camera first, confirm live video and recording, then repeat.

## Prerequisites

- The camera is powered, on the network, and reachable from the recording PC
  (`ping 192.168.1.64` should succeed).
- The camera's IP address, ONVIF/RTSP port, username and password.
- The camera's stream path if it is not ONVIF (see the vendor manual).
- Free channel capacity on your plan — see [Getting Started](/docs/getting-started/).

## Step-by-step instructions

### Step 1 — Put the camera on a fixed address

Give the camera a static IP, or a DHCP reservation on your router. A camera that changes address
after a power cut looks offline the next morning.

### Step 2 — Open the add-camera dialog

In the client, open **Cameras → Add camera**. Choose the source type from the table above.

### Step 3 — Fill in the connection details

For an **ONVIF** camera:

| Field | Example | Notes |
|---|---|---|
| IP address | `192.168.1.64` | Not the hostname, unless DNS is reliable |
| ONVIF port | `80` | Some cameras use `8080` |
| Username | `admin` | The camera account, not a domain account |
| Password | `••••••` | Case sensitive |
| Profile | `mainStream` | Substream is cheaper for live view |

For an **RTSP** camera:

```
rtsp://admin:password@192.168.1.64:554/Streaming/Channels/101
```

Common vendor paths:

| Vendor | Typical path |
|---|---|
| Hikvision | `/Streaming/Channels/101` (main), `/102` (sub) |
| Dahua | `/cam/realmonitor?channel=1&subtype=0` |
| Axis | `/axis-media/media.amp` |
| Generic | `/stream1`, `/live/ch00_0` |

### Step 4 — Choose the stream profile

| Use | Resolution | Frame rate | Notes |
|---|---|---|---|
| Main stream | 1080p | 15–20 FPS | Recording and AI analysis |
| Sub stream | 640×360 | 8–10 FPS | Live wall, remote viewing |

Selecting the substream for live grids keeps the server responsive when 16 tiles are open. AI
events should always run on the main stream.

### Step 5 — Preview and save

1. Choose **Test** (or **Preview**). Video should appear within a few seconds.
2. Name the camera meaningfully: `Gate — entry`, `Reception — wide`, `Dock — plate`. Names appear
   in alerts and search results.
3. Save. The camera appears in the live grid with a recording indicator.

### Step 6 — Set recording behaviour for this camera

| Mode | When it is right |
|---|---|
| Continuous | Entrances, cash desks, anywhere an incident may be missed |
| Motion only | Corridors, car parks, low-traffic areas |
| Scheduled | Areas that only matter outside office hours |

Auto disk cleanup applies across all cameras, so mix modes rather than lowering quality
everywhere.

## Configuration examples

| Camera | Type | Resolution / FPS | Recording | AI |
|---|---|---|---|---|
| Gate — entry | ONVIF | 1080p / 20 | Continuous | Person + vehicle |
| Gate — plate | RTSP | 1080p / 25 | Motion | LPD |
| Reception — wide | ONVIF | 1080p / 15 | Continuous | Person |
| Corridor | RTSP substream | 720p / 10 | Motion | Off |
| Dock | ONVIF | 1080p / 15 | Schedule 18:00–06:00 | Person |

## What you should see

- The camera tile shows live video, not a black rectangle or a spinner.
- A recording indicator is active and the storage figure increases.
- The camera appears in [Smart Search](/docs/search-and-investigation/) with today's timeline.
- After a restart of the application, the camera reconnects without manual intervention.

## Troubleshooting

| Error | Cause | Fix |
|---|---|---|
| `401 Unauthorized` | Wrong camera username or password | Re-enter; test in the camera's own web page first |
| `Connection timed out` | Wrong IP, port or VLAN | Ping the camera; check the ONVIF port |
| Video is black but connected | Wrong stream path or unsupported codec | Switch the camera to H.264; try the substream path |
| Frequent disconnects | Network saturation or camera limit | Lower FPS/resolution, or move the camera to a dedicated switch |
| "Channel limit reached" | Plan capacity used | Remove a camera or upgrade the plan |
| Works in the camera's web page, not here | Different credentials for ONVIF vs web UI | Create an ONVIF user on the camera |

## Related guides

- [Live Monitoring](/docs/live-monitoring/)
- [AI Event Detection](/docs/ai-event-detection/)
- [System Requirements](/docs/system-requirements/)
- [Troubleshooting](/docs/troubleshooting/)

**Next step:** [AI Event Detection](/docs/ai-event-detection/) →